Product Code: 2994
INVERTER, UPS, AVR & CHARGER
Overview
-
Pure sine wave inverter,
-
UPS, AVR (Stabilizer) and charger function
-
Generator compatible
-
Low power self-consumption
-
Fast changeover, guarantees uninterrupted power supply
-
True C.R.G.O Toroidal transformer design provides high efficiency, low static loss, much more energy saving than old square transformer type design.
-
Intelligent 3 stage charger protects your battery
-
32-bit high speed CPU control, swift response, more accurate detection
-
Color LED, user friendly operation interface, displays clearly device’s working status, input & output voltage, loading status, battery status etc.
Buy this product through any of the following:
-
Telephone Order - Call 0803 2170 129
-
Buyright Showrooms (Lagos, Port Harcourt or Abuja) Click Here
-
Order from KONGA Click Here
-
Order from JUMIA Click Here
₦ 94,700.00 |
|
 |
|
Model |
2KVA |
Rated Capacity |
2000VA |
Rated Power |
1400W |
Transformer |
C.R.G.O |
Interface |
LED graphic |
Display Status |
working & loading & battery |
Input |
Voltage |
140~275 Vac |
Frequency |
45~65 Hz |
Output |
Voltage |
220Vac ±3% for inverter;190V-245V for avr |
Frequency |
50/60 Hz ± 0.3Hz, subject to the main |
Wave Form |
Pure sinve wave |
Wave Distortion |
≤ 3% |
Protection |
overload / high temperature / output high voltage / output low voltage / battery low voltage / short circuit / over-charge / over-discharge / reversed polarity |
Transfer Time |
≤ 4ms |
Battery Voltage |
24V DC |
Charge Voltage |
27.6V±0.6V |
Low Battery Voltage Limit |
21.8V ±0.6V |
Battery Low Voltage Protection Point |
20.5V ±0.6V |
Charge Current |
Max. 10A/15A/20A optional |
Cooling System |
Yes |
Environmental |
Operating Temperature |
0 - 40 ℃ |
Relative Humidity |
10%~90% RH, non-condensing |
Storage Temperature |
﹣15 - 45 ℃ |
Model |
2KVA |
Rated Capacity |
2000VA |
Rated Power |
1400W |
Transformer |
C.R.G.O |
Interface |
LED graphic |
Display Status |
working & loading & battery |
Input |
Voltage |
140~275 Vac |
Frequency |
45~65 Hz |
Output |
Voltage |
220Vac ±3% for inverter;190V-245V for avr |
Frequency |
50/60 Hz ± 0.3Hz, subject to the main |
Wave Form |
Pure sinve wave |
Wave Distortion |
≤ 3% |
Protection |
overload / high temperature / output high voltage / output low voltage / battery low voltage / short circuit / over-charge / over-discharge / reversed polarity |
Transfer Time |
≤ 4ms |
Battery Voltage |
24V DC |
Charge Voltage |
27.6V±0.6V |
Low Battery Voltage Limit |
21.8V ±0.6V |
Battery Low Voltage Protection Point |
20.5V ±0.6V |
Charge Current |
Max. 10A/15A/20A optional |
Cooling System |
Yes |
Environmental |
Operating Temperature |
0 - 40 ℃ |
Relative Humidity |
10%~90% RH, non-condensing |
Storage Temperature |
﹣15 - 45 ℃ |