0 Items
PRAG 1KVA/12V Inverter
Overview
- Pure sine wave inverter,
- UPS, AVR (Stabilizer) and charger function
- Generator compatible
- Low power self-consumption
- Fast changeover, guarantees uninterrupted power supply
- True C.R.G.O Toroidal transformer design provides high efficiency, low static loss, much more energy saving than old square transformer type design.
- Intelligent 3 stage charger protects your battery
- 32-bit high speed CPU control, swift response, more accurate detection
- Color LED, user friendly operation interface, displays clearly device’s working status, input & output voltage, loading status, battery status etc.
Buy this product through any of the following:
-
Telephone Order - Call 0803 2170 129
- Buyright Showrooms (Lagos, Port Harcourt or Abuja) Click Here
- Order from KONGA Click Here
- Order from JUMIA Click Here
Features
Model | 1KVA |
Rated Capacity | 1000VA |
Rated Power | 700W |
Transformer | C.R.G.O |
Interface | LED graphic |
Display Status | working & loading & battery |
Input | |
Voltage | 140~275 Vac |
Frequency | 45~65 Hz |
Output | |
Voltage | 220Vac ±3% for inverter;190V-245V for avr |
Frequency | 50/60 Hz ± 0.3Hz, subject to the main |
Wave Form | Pure sinve wave |
Wave Distortion | ≤ 3% |
Protection | |
overload / high temperature / output high voltage / output low voltage / battery low voltage / short circuit / over-charge / over-discharge / reversed polarity | |
Transfer Time | ≤ 4ms |
Battery Voltage | 12V DC |
Charge Voltage | 13.8V±0.5V |
Low Battery Voltage Limit | 10.9V ±0.3V |
Battery Low Voltage Protection Point | 10.2V ±0.3V |
Charge Current | Max. 10A/15A/20A optional |
Cooling System | Yes |
Environmental | |
Operating Temperature | 0 - 40 ℃ |
Relative Humidity | 10%~90% RH, non-condensing |
Storage Temperature | ﹣15 - 45 ℃ |
×
Specifications
Model | 1KVA |
Rated Capacity | 1000VA |
Rated Power | 700W |
Transformer | C.R.G.O |
Interface | LED graphic |
Display Status | working & loading & battery |
Input | |
Voltage | 140~275 Vac |
Frequency | 45~65 Hz |
Output | |
Voltage | 220Vac ±3% for inverter;190V-245V for avr |
Frequency | 50/60 Hz ± 0.3Hz, subject to the main |
Wave Form | Pure sinve wave |
Wave Distortion | ≤ 3% |
Protection | |
overload / high temperature / output high voltage / output low voltage / battery low voltage / short circuit / over-charge / over-discharge / reversed polarity | |
Transfer Time | ≤ 4ms |
Battery Voltage | 12V DC |
Charge Voltage | 13.8V±0.5V |
Low Battery Voltage Limit | 10.9V ±0.3V |
Battery Low Voltage Protection Point | 10.2V ±0.3V |
Charge Current | Max. 10A/15A/20A optional |
Cooling System | Yes |
Environmental | |
Operating Temperature | 0 - 40 ℃ |
Relative Humidity | 10%~90% RH, non-condensing |
Storage Temperature | ﹣15 - 45 ℃ |
×
Model | 1KVA |
Rated Capacity | 1000VA |
Rated Power | 700W |
Transformer | C.R.G.O |
Interface | LED graphic |
Display Status | working & loading & battery |
Input | |
Voltage | 140~275 Vac |
Frequency | 45~65 Hz |
Output | |
Voltage | 220Vac ±3% for inverter;190V-245V for avr |
Frequency | 50/60 Hz ± 0.3Hz, subject to the main |
Wave Form | Pure sinve wave |
Wave Distortion | ≤ 3% |
Protection | |
overload / high temperature / output high voltage / output low voltage / battery low voltage / short circuit / over-charge / over-discharge / reversed polarity | |
Transfer Time | ≤ 4ms |
Battery Voltage | 12V DC |
Charge Voltage | 13.8V±0.5V |
Low Battery Voltage Limit | 10.9V ±0.3V |
Battery Low Voltage Protection Point | 10.2V ±0.3V |
Charge Current | Max. 10A/15A/20A optional |
Cooling System | Yes |
Environmental | |
Operating Temperature | 0 - 40 ℃ |
Relative Humidity | 10%~90% RH, non-condensing |
Storage Temperature | ﹣15 - 45 ℃ |
×